Physical specifications and mounting
The following physical specifications and mounting requirements help you choose a suitable installation location for the Hera 204.
Physical specifications
Specification
Details
Dimensions (W × D × H)
99 × 90 × 28 mm
Weight
250 g
Enclosure
Aluminium
Power supply
12 V DC Molex Mini-Fit Jr wall adapter
Input voltage range
9–24 V DC
Maximum power consumption
10 W
Operating temperature
−20°C to 55°C
Operating humidity
5% to 95%, non-condensing
Mounting requirements
The Hera 204 supports direct mounting and bottom or side DIN rail mounting using an optional mounting kit.
Choose a location that:
Is away from direct sunlight and other heat sources.
Provides sufficient ventilation around the router.
Is not exposed to excessive dust, liquids, or industrial exhaust.
Is within one metre of a mains power outlet.
Keeps cellular antennas at least one metre away from people during normal operation.
Allows access to the router’s ports, SIM slot, and reset button.
Do not mount the Hera 204 more than two metres above the floor. A falling router could cause injury.
The supplied antennas are not designed for outdoor use. If you use an outdoor antenna, ensure adequate lightning protection.
Use only an Eseye-approved Limited Power Source mains adapter. It must comply with IEC/UL 60950-1 or IEC/UL 62368-1. Do not modify the power adapter.
SIM card orientation
Insert an external SIM card in the orientation shown:

After mounting the router, see Connect Hera 204.
Last updated
Was this helpful?