Serial Ports

The Hera 604 provides two configurable serial ports. Open Basic Settings > Serial Ports > Serial port 1 or Serial port 2 to match a port to the connected equipment.

Important: The serial mode, baud rate, data bits, parity, stop bits, and electrical controls must match the connected device and wiring. Incorrect electrical-mode or termination settings can prevent communication. Use the values specified in the equipment design or installation record.

Field
Example or available values
Description

Device

/dev/eser0 or /dev/eser1

Internal device assigned to serial port 1 or serial port 2.

Stop bits

1, 1.5, or 2

Number of stop bits used to mark the end of each transmitted character.

Data bits

5, 6, 7, or 8

Number of data bits in each character.

Parity

None, Even, Odd, Forced 0, or Forced 1

Parity method used for serial error checking.

Baud rate

9600

Communication speed in bits per second. Select the rate required by the connected device.

Timeout (seconds)

100

Time the router waits before treating an inactive serial operation as timed out.

Mode

RS232, RS422, or RS485

Electrical signalling standard used by the connected serial equipment.

Duplex

Half or Full

Determines whether the link transmits and receives alternately or at the same time.

Loop

Enabled or Disabled

Enables serial loopback behaviour. Use only for an approved test configuration.

EN_A

Enabled or Disabled

Hardware control for serial transceiver channel A. Use the value specified for the selected electrical mode and wiring.

EN_B

Enabled or Disabled

Hardware control for serial transceiver channel B. Use the value specified for the selected electrical mode and wiring.

A_DE

Enabled or Disabled

Driver-enable control for serial channel A. Use the value specified for the selected electrical mode and duplex arrangement.

Termination

Enabled or Disabled

Enables line termination where required by the RS422 or RS485 wiring design.

Termination TX

Enabled or Disabled

Enables transmit-side termination where required by the wiring design.

Select Save after configuring the port.