EMQ – publish a message to singletopic
Publish a message to the system singlepubtopic. singlepubtopic is a predefined topic for single-subscription systems, where the host is not expected to register a publish topic with +EMQPUBOPEN. The publish topic (singlepubtopic) and QoS (singlepubtopicqos) are defined in the configuration file. For more information, see the [MQTT] section, Using the Cinterion® PLS62‑W Wireless Module configuration file. The index is not required.
Test
AT+EMQ=?
OK
+EMQ:"<pubdata>"
Read
AT+EMQ?
OK
or
ERROR
Write
AT+EMQ=<pubdata>
where
<pubdata> – is the published message. The maximum payload length is 1000 characters. All characters must be printable.
AnyNet SMARTconnect™ handles <pubdata> as ASCII-hex if it contains an even number of valid ASCII-hex characters (0-9, a-f, A-F). ASCII-hex is converted to binary for transmission.
AnyNet SMARTconnect™ handles all other data as text. For text messages, \ (escape characters) are removed.
OK – command result
SEND OK – subsequent URC that is sent when publish occurs. This will not happen immediately if AnyNet SMARTconnect™ is offline.
or
ERROR
Example
AT+EMQ="{\"BatteryPower\": \"Low\"}"
OK
SEND OKLast updated
Was this helpful?