Eseye-enabled module operating parameters are contained in a module-specific configuration file.
The Eseye-enabled Cinterion® PLS62‑W Wireless Module operating parameters are contained in the configuration file, which you can find here: a:/config.ini.
You can use the configuration file to set the following parameters:
Operational
Network
Application
Host
Config
MQTT
UDP
SMS
Location
You can deploy the configuration file using either: http or https.
You can trigger an update using MQTT.
The .ini file is divided into sections, denoted by square brackets. Each section has parameters listed underneath it.
[operation]
Operational parameters
apptrace
Application trace level (0-4), for Support purposes. Leave as 1 (default).
attrace
AT command trace level (0-4), for Support purposes. Leave as 1 (default).
nvqueuemaxsize
Maximum size (in bytes) of the NV data TX queue. Default: 2048 bytes. If the queue size is exceeded, the oldest messages are dropped.
Note: The default size is intended for devices sending small message payloads. Increase this amount if you are using devices that send large message payloads.
For large messages, you must ensure that the maximum NV store size is at least four times the largest expected published message size, plus eight bytes for the storage header. For example, for 1000 byte messages, set a minimum nvqueuemaxsize of 4032.
nvqueue_enable
The non-volatile memory NV queue is enabled by default to prevent message loss during a power-cycle or reboot. Use:
0 – NV queue is not enabled
1 (default) – NV queue is enabled
nvqueuetrace
Non-volatile (NV) queueing subsystem trace level (0-4), for Support purposes. Leave as 1 (default).
mode
Operating mode, either:
mqtt
none (default)
teletrace
Data connection subsystem trace level (0-4), for Support purposes. Leave as 1 (default).
[network]
Network parameters
apn
Access Point Name
apnuser
APN user name
apnpass
APN password
tech
Preferred technology for connecting to the cellular network, either:
2G – 2G only
LTE – LTE only
any (default) – either 2G or LTE
[application]
Application parameters
fotaport
Modem firmware OTA image protocol IP port. Default: 80
fotaurl
Modem firmware OTA image URL, either: http or https
Note: If this parameter is not set, it is not included in the configuration file.
updateport
Application firmware update protocol IP port. Default: 80
updateurl
Application firmware update URL, either: http or https
Note: If this parameter is not set, it is not included in the configuration file.
[host]
Host parameters
updateport
Host firmware update protocol IP port. Default: 80
updateurl
Host firmware update URL, either: http or https
Note: If this parameter is not set, it is not included in the configuration file.
[config]
Configuration file update parameters
updateport
Configuration file update protocol IP port. Default: 80
updateurl
Configuration file update URL, either: http or https
Note: If this parameter is not set, it is not included in the configuration file.
[mqtt]
MQTT parameters
awsjobs
AWS jobs topics subscription and for processing jobs instructions, either:
0 – Do not subscribe to AWS jobs topics
1 (default) – Subscribe to AWS jobs topics
awsshadow
AWS shadow mode for reporting a set value to the device shadow/twin, either:
simple (default) – Report only the content of the state reported object
complete – Report the complete JSON data
off – Do not report a set value
For more information, see EMQPERSIST – report a set value to the device shadow .
clientid
MQTT client ID. This parameter is ignored when AnyNet SMARTconnect™ connects to Google IoT.
Note: If this parameter is not set, it is not included in the configuration file.
keepalive
Maximum expected time (in seconds) between received keepalives before AnyNet SMARTconnect™ assumes the MQTT connection is down. Default: 1200
mqttlwtmessage
LWT message for notifying subscribed clients about an unexpected loss of connection. To enable LWT, you must configure <mqttlwttopic> and <mqttlwtmessage>. Use:
<message> – the MQTT message that is discarded if the client disconnects gracefully
Note: If this parameter is not set, it is not included in the configuration file.
mqttlwtqos
Last will and testament (LWT) message QoS, defining the guarantee of message delivery. Either:
0 (default) – at most once, no guarantee of message receipt
1 – the message is sent or delivered to the receiver one or more times
mqttlwtretain
LWT message retained message flag, either:
0 (default) – message flag not enabled. This is a required setting for AWS only.
1 – message flag enabled
mqttlwttopic
Last will and testament (LWT) topic path for notifying subscribed clients about an unexpected loss of connection. To enable LWT, you must configure <mqttlwttopic> and <mqttlwtmessage>. Use:
topic – the topic path
Note: If this parameter is not set, it is not included in the configuration file.
mqttsettingstopic
Alternative to the AWS IoT shadow for configuring AnyNet SMARTconnect™ behaviour. Subscription to this single topic enables commands to be sent from the cloud broker to AnyNet SMARTconnect™ via MQTT. Use either:
topic – the subscribe topic title
port
MQTT IP port. Default: 8883
singlepubtopic
Predefined topic for single-publish systems. The <topicsuffix> is not added as a suffix to the singlepubtopic name, however you can use a token instead.
Note: If this parameter is not set, it is not included in the configuration file.
singlepubtopicqos
QoS for single publish, defining the guarantee of message delivery. Either:
0 (default) – at most once, no guarantee of message receipt
1 – the message is sent or delivered to the receiver one or more times
singlesubtopic
Predefined topic for single subscription systems.
Note: If this parameter is not set, it is not included in the configuration file.
singlesubtopicqos
Quality of Service (QoS) for single subscription, defining the guarantee of message delivery. Either:
0 (default) – at most once, no guarantee of message receipt
1 – the message is sent or delivered to the receiver one or more times
topicsuffix
Appends a topic path to the end of the requested topic to uniquely identify the thing on the broker.
thingname (default) – the cloud thingName
imei – the unique IMEI number for the device
none – the exact topic is used, with no suffix appended
Note: If topicsuffix is not present in the configuration file, then thingname is appended on the requested topic.
tracelevel
MQTT trace level (0-4), for Support purposes. Leave as 1 (default).
urcautoformat
For formatting URCs, either:
0 – sends all URCs as ASCII-hex within quotes
For example: '{"key1":"val1"}' will appear in a URC as '+EMQ:<id>,15\r\n"7B226B657931223A2276616C31227D"'
1 (default) – this option enables sending URCs as either ASCII-hex or text, depending on the received payload.
If the received payload is printable text (including JSON), then the URC data is sent as text.
For example:
'{"key1":"val1"}'will appear in a URC as'+EMQ:<id>,15\r\n{"key1":"val1"}'For JSON, the maximum payload is 1012 characters. Escaped quotes count as 1 character:
\"If the received payload is binary data, then the URC data is sent as ASCII hex.
[udp]
UDP parameters
port
UDP IP port. Default: 12401
url
UDP IP address
Note: If this parameter is not set, it is not included in the configuration file.
[sms]
SMS parameters
enable
For configuring SMS handling, either:
0 – SMS handling disabled
1 (default) – SMS handling enabled
tracelevel
SMS trace level (0-4), for Support purposes. Leave as 1 (default).
whitelist
Comma-separated list of one or more MSISDN values from which SMS is accepted. For example: 447624499970,447624499971
[location]
Location parameters
enable
For configuring location, either:
0 (default) – location disabled
1 – location enabled; Cinterion® PLS62‑W Wireless Module will always try to establish a GPS/GNSS location while running
tracelevel
Location trace level (0-4), for Support purposes. Leave as 1 (default).
Last updated